Meta Data
Title in national language: 
《電力供應規例》
Проект документа: 
No
Пересмотр более раннего документа?: 
No
Год составления проекта документа: 
1990
Год вступления в силу: 
2021
Виды актов по количеству участников: 
National
Тип документа: 
Rule/Regulation
Экономический сектор: 
Power
Виды энергоресурсов: 
Power
Подготовлен: 
Government of Hong Kong
Ссылка на документ: 
Сводный обзор: 
These regulations were made under section 3 of the repealed Electricity Supply Ordinance (Cap. 103, 1976 Ed.). See section 36(1) of the Interpretation and General Clauses Ordinance (Cap. 1) and section 59(1) of the Electricity Ordinance, enacted in 1990 (Cap. 406). The entail various specifications on electricity supply, including supply voltage standards.
Доступ
Energy service quality targets: 
The company shall supply low voltage electricity to the main incoming terminals of an owner’s electrical installation at a frequency of 50Hz (+/-2%) at either or both of the following— (a)220V (+/-6%) root mean square alternating current between a phase conductor and earth for a single phase supply; and (b)220V (+/-6%) root mean square alternating current between a phase conductor and earth and 380V (+/-6%) alternating current between phase conductors for a 3 phase supply. (2)The company shall supply high voltage electricity to the main incoming terminals of an owner’s electrical installation at a frequency of 50Hz (+/-2%).