NOTE: Images, tables, and charts may not display correctly. Please see PDF document for full details.
Code for Environmental Sustainability of Buildings Addendum No. 1
Effective from 1 September 2014
Applicable to 3rd Edition
This Addendum shall be read in conjunction with the Code for Environmental Sustainability of Buildings and shall form part of the Code.
Amendments to the Code
Coefficient of Performance (COP) range | Point Allocation |
COP100% ≥ 3.06 & 3.76 > Weighted COP ≥ 3.34 |
4 |
COP100% ≥ 3.34 & Weighted COP ≥ 3.76 |
8 |
(1) Purpose of amendments
The purpose of the amendments is to allow alternative scoring methodology for meeting the criteria under ‘RB 1-2 Naturally Ventilated Design and Air-Conditioning System’.
(a) Item 1-2(a) Option 2(ii) under the ‘RB 1-2 Naturally Ventilated Design and Air-Conditioning System in Table 4.1.6(a) on Page 9 of the Code shall be replaced as provided below. Changes are highlighted in blue.
Table 4.1.6(a) : Residential Building Criteria
Part 1 – Energy Efficiency | Green Mark Points |
RB 1-2 Naturally Ventilated Design and Air- Conditioning System Option 2 – Ventilation Design (without the use of simulation modeling) and Efficient Use of Air-Conditioning System
(a) Dwelling Unit Indoor Comfort Enhance dwelling unit indoor comfort through the provision of good natural ventilation design and energy efficient air-conditioners
(ii) Provision of air-conditioning system Use of energy efficient air-conditioners that meet the prescribed energy performance standards.
Note (1) : Option 2(ii) is not applicable for developments where air-conditioners are not provided. Points will be scored and prorated accordingly under Option 2(i) |
Extent of Coverage : At least 80% of the air-conditioners used in all dwelling units Air-conditioners labelled with : Three Ticks – 4 points Four Ticks – 8 points
OR |
(b) Item 1-2(a) Option 2 (ii) under the ‘RB 1-2 Naturally Ventilated Design and Air-Conditioning System’ on Page 57 of the Code shall be replaced as provided below. Changes are highlighted in blue.
Requirements
1-2 (a) Dwelling Unit Indoor Comfort
Extent of coverage : At least 80% of air-conditioners used in all dwelling units.
Option 2(ii) Provision of energy efficient air-conditioning system
Up to 8 points can be scored for the use of the air-conditioners that are certified under the Singapore Energy Labelling Scheme based on the following rating.
OR
Up to 8 points can be scored for the provision of air-conditioning system with Coefficient of Performance (COP) that meet the prescribed energy performance standards stated in the following Table 1-2.
Notes :
(1) Coefficient of Performance or COP refers to the ratio of the total cooling capacity expressed in Watts to the total effective input power expressed in Watts, and as specified in the test report.
(2) Weighted COP refers to the sum of 0.4 × COP at full-load cooling capacity and 0.6 × COP at part-load cooling capacity i.e. Weighted COP = 0.4 x COP100% + 0.6 x COP50%
Option 2(ii) is not applicable for developments where air-conditioners are not provided. Points can be scored and prorated accordingly under Option 2(i).
RB 1-2 NATURALLY VENTILATED DESIGN AND AIR-CONDITIONING SYSTEM
Energy Efficiency Rating | Point Allocation |
✓✓✓ ✓✓✓✓ | 4 8 |
Table 1-2 – Prescribed Energy Performance Standards for Air-Conditioning System |
Coefficient of Performance (COP) range | Point Allocation |
COP100% ≥ 3.06 & 3.76 > Weighted COP ≥ 3.34 | 4 |
COP100% ≥ 3.34 & Weighted COP ≥ 3.76 |
8 |
Documentary evidence requirements for Item 1-2(a) Option 2(ii) under the ‘RB 1-2 Naturally Ventilated Design and Air-Conditioning System’ on Page 57 of the Code shall be replaced as provided below. Changes are highlighted in blue.
Documentary Evidences
For 1-2(a) Option 2(ii) – Provision of Air-Conditioning Systems
Extracts of the tender specification showing the types of air-conditioners provided for all dwelling units of the development;
Technical product information and schedule of air-conditioners showing the numbers, types and approved tick-rating as registered; and
Testing report endorsed by the testing laboratory showing the results of tests carried out in accordance with applicable test standards as prescribed in the Energy Conservation (Energy Labelling and Minimum Performance Standards for Registrable Goods) Regulation.